Section 366.0503. Smoke alarms.
Latest version.
- These are department rules in addition to the requirements in IEBC section 503:(1) No smoke alarm, including an alarm that exists on September 1, 2011, may remain in service for more than that specified by the manufacturer.(2) The replacement of a smoke alarm that uses a battery as its primary power source shall be a new smoke alarm that complies with UL 217 and either of the following:(a) The alarm is hardwired in accordance with IBC section 907.2.11.4 and has backup power in accordance with that section.(b) The alarm uses, as its primary power source, a non-replaceable, non-removable battery that is capable of powering the alarm for at least 10 years.