Section 362.1405. Exterior walls.
Latest version.
- (1) This is a department exception in addition to the exceptions in IBC section 1405.3: Where other approved means to avoid condensation in unventilated framed wall, floor, roof and ceiling cavities and box sills are provided.(2) This is a department rule in addition to the requirements in IBC section 1405.14.1: Polystyrene sheathing may be utilized as the required backing material for vinyl siding provided all of the following characteristics and conditions are met:(a) The sheathing is extruded, rigid and cellular.(b) The sheathing is type IV, as specified in ASTM C578.(c) The sheathing has a thickness of at least one inch.(d) The sheathing is installed with an on-center stud spacing of 16 inches or less.(e) The mean roof height of the building is 40 feet or less.(f) The building wall has a wind exposure category of B or C, as established in IBC section 1609.4; and the building is not sited on the upper half of an isolated hill or escarpment meeting conditions 1, 2, and 3 in IBC section 1609.1.1.1.