Section 321.32. Factory-built fireplaces.


Latest version.
  • Factory-built fireplaces consisting of a fire chamber assembly, one or more chimney sections, a roof assembly and other parts shall be tested and listed by a nationally recognized testing laboratory.
    (1) Fireplace assembly and maintenance. The fireplace assembly shall be erected and maintained in accordance with the conditions of the listing.
    (a) All joints between the wall or decorative facing material and the fireplace unit shall be completely sealed, firestopped or draft-stopped with a noncombustible caulk or equivalent.
    (b) Doors installed on factory built fireplaces shall conform with the terms of the listing and the manufacturers installation instructions for the fireplace unit.
    (2) Distance from combustibles. Portions of the manufactured chimney extending through combustible floors or roof/ceiling assemblies shall be installed in accordance with the distances listed on the chimney in order to prevent contact with combustible materials.
    (3) Hearth extensions. Hearth extensions shall be provided in accordance with the manufacturer's listing. Where no hearth extension is specified in the listing, a hearth extension shall be provided in accordance with s. SPS 321.29 (6) .
Cr. Register, November, 1979, No. 287 , eff. 6-1-80; renum. from Ind 21.30 and r. and recr. (3), Register, February, 1985, No. 350 , eff. 3-1-85; cr. (1) (a) and (b), am. (3) and Table 21.32-1, Register, January, 1989, No. 397 , eff. 2-1-89; r. and recr. Register, March, 1992, No. 435 , eff. 4-1-92; correction in (3) made under s. 13.92 (4) (b) 7. , Stats., Register December 2011 No. 672 .