Section 316.547. Agricultural buildings.
Latest version.
- This is a department exception to the requirements in NEC 547.5 (G):Exception: Ground-fault circuit-interrupter protection is not required for a single receptacle providing power for an electric fence controller used for livestock containment where an accessible ground-fault circuit-interrupter protected receptacle is located within 900 mm (3 ft) of the non-GFCI protected receptacle.
CR 13-042
: cr.
Register November 2013 No. 695
, eff. 12-1-13.