Wisconsin Administrative Code (Last Updated: January 10, 2017) |
![]() |
Agency SPS. Department of Safety and Professional Services |
![]() |
Chapters 301-. Safety, Buildings, and Environment |
![]() |
Chapters SPS319. General, Part I |
![]() |
Chapter SPS307. Explosives And Fireworks |
![]() |
SubChapter IV. Blasting Resultants |
Section 307.43. Instrumentation.
Latest version.
- All seismographs used to determine compliance with this subchapter shall meet the following minimum specifications:(1) Seismic frequency range: 2 to 200 Hz ( ± 3 Hz).(2) Acoustic frequency range: 2 to 200 Hz ( ± 1 Hz).(3) Velocity range: 0.02 to 4.0 inches/second.(4) Sound range: 110 to 140 dB linear.(5) Transducers: Three mutually perpendicular axes.(6) Recording: Provide time-history of waveform.(7) Calibration: Be laboratory calibrated as often as necessary, but at least once every 12 months according to manufacturer's recommendations.
Note
Due to an error in
CR 06-120
, dB was changed to Hz in sub. (2).