![]() |
Wisconsin Administrative Code (Last Updated: January 10, 2017) |
![]() |
Agency NR. Department of Natural Resources |
![]() |
Chapters 400-499. Environmental Protection – Air Pollution Control |
![]() |
Chapter 465. National Emission Standards For Hazardous Air Pollutants For General Surface Coating Processes |
![]() |
SubChapter I. Wood Furniture Manufacturing Operations |
Section 465.03. Symbols.
Latest version.
- The symbols used in this subchapter have the following meanings:(1) "ac" means after the control system is installed and operated.(2) "A k " is the area of each natural draft opening k in a total enclosure, in square meters.(3) "bc" means before control.(4) "C aj " is the concentration of VHAP in gas stream j exiting the control device, in parts per million by volume.(5) "C bi " is the concentration of VHAP in gas stream i entering the control device, in parts per million by volume.(6) "C c " is the VHAP content of a finishing material c in kilograms of VHAP per kilogram of coating solids (kg VHAP/kg solids), as supplied. Also given in pounds of VHAP per pound of coating solids (lb VHAP/lb solids).(7) "C di " is the concentration of VHAP in gas stream i entering the control device from the affected source, in parts per million by volume.(8) "C fk " is the concentration of VHAP in uncontrolled gas stream k emitted directly to the atmosphere from the affected source, in parts per million by volume.(9) "E" is the emission limit achieved by an emission point or a set of emission points, in kg VHAP/kg solids (lb VHAP/lb solids).(10) "F" is the control device efficiency, expressed as a fraction.(11) "FV" is the average inward face velocity across all natural draft openings in a total enclosure, in meters per hour.(12) "G" is the VHAP content of a contact adhesive, in kg VHAP/kg solids (lb VHAP/lb solids), as applied.(13) "M c " is the mass of solids in finishing material c used monthly, kg solids/month (lb solids/month).(14) "N" is the capture efficiency, expressed as a fraction.(15) "Q aj " is the volumetric flow rate of gas stream j exiting the control device, in dry standard cubic meters per hour.(16) "Q bi " is the volumetric flow rate of gas stream i entering the control device, in dry standard cubic meters per hour.(17) "Q di " is the volumetric flow rate of gas stream i entering the control device from the emission point, in dry standard cubic meters per hour.(18) "Q fk " is the volumetric flow rate of uncontrolled gas stream k emitted directly to the atmosphere from the emission point, in dry standard cubic meters per hour.(19) "Q in i " is the volumetric flow rate of gas stream i entering the total enclosure through a forced makeup air duct, in standard cubic meters per hour, wet basis.(20) "Q out j " is the volumetric flow rate of gas stream j exiting the total enclosure through an exhaust duct or hood, in standard cubic meters per hour, wet basis.(21) "R" is the overall efficiency of the control system, expressed as a percentage.(22) "S" is the VHAP content of a solvent, expressed as a weight fraction, added to finishing materials.(23) "W" is the amount of solvent, in kilograms (pounds), added to finishing materials during the monthly averaging period.
History:
CR 00-160
: cr.
Register August 2001 No. 548
, eff. 9-1-01;
CR 03-037
: am. (intro.)
Register March 2004 No. 579
, eff. 4-1-04.