Section 286.12. Standards of performance.  


Latest version.
  • The following effluent limitations for all or specific subcategories establish the quantity or quality of pollutants or pollutant properties which may be discharged by a facility which is a new source subject to the provisions of this chapter.
    (1)  The pH of all discharges shall be within the range of 6.0 to 9.0
    (2)  The 30-day average and daily maximum limitations for BOD 5, suspended solids, and other parameters are set forth in table 1.
    (3)  The limitations of table 1 are in lbs/1000 lbs or kg/1000 kg or raw material for subcategories (e), (f), (g), (j) and (k) and of product for the other subcategories of s. NR 286.02 .
    (4)  The limitations for lead in table 1 apply only to discharges attributable to the manufacture of lead sheathed hose.
    (5)  The limitations for chromium in table 1 apply only to facilities using a chromic acid form cleaning operation.
History: Cr. Register, June, 1976, No. 246 , eff. 7-1-76.