Section 276.11. Effluent limitations, best available treatment.  


Latest version.
  • The following effluent limitations for all or specific subcategories establish except as provided in s. NR 276.06 the quantity or quality of pollutants or pollutant properties which may be discharged to surface waters by a facility subject to the provisions of this chapter after application to process wastes of the best available technology economically achievable.
    (1)  There shall be no discharge of wastes from facilities in subcategories (1), (2), and (3).
    (2)  There shall be no discharge of waste from facilities in subcategories (4) and (5) except in accordance with s. NR 276.07 (2) and (3) .
    (3)  For discharges from facilities in subcategory (6) the pH shall be within the range of 6.0-9.0 and the quantities of suspended solids, total phosphorus, and fluoride shall not exceed daily averages of respectively 0.18, 0.28, and 0.11 lbs/1000 lbs or kg/1000 kg of product nor corresponding daily maxima of 0.35, 0.56, and 0.21.
History: Cr. Register, June, 1976, No. 246 , eff. 7-1-76.