Section 258.12. Standards of performance.  


Latest version.
  • The following effluent limitations when applied in accordance with s. NR 258.06 establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this chapter.
    (1)  The pH of all discharges shall be within the range of 6.0 to 9.0.
    (2)  The fecal coliform of all discharges except those from the small processor subcategory shall not exceed an MPN of 400/100 ml.
    (3)  The BOD 5 , suspended solids, oil and grease, and ammonia 30 day average limitations are set forth in table 3. The daily maximum limitations are 2 times the 30 day average values.
    (4)  For a renderer who conducts hide curing the effluent limitations for the renderer subcategory in table 3 shall be increased by adding;
    (a) To the limitation for BOD 5 the value resulting from dividing the number of hides cured by their weight in pounds and multiplying by 7.9, or by their weight in kilograms and multiplying by 3.6, and
    (b) To the limitations for suspended solids the value resulting from dividing the number of hides cured by their weight in pounds and multiplying by 13.6, or by their weight in kilograms and multiplying by 6.2.
History: Cr. Register, June, 1976, No. 246 , eff. 7-1-76.

Note

(1) Limitation is calculated using the formula 0.21 ) 0.23 (V-0.4) where V is the lb processed meat products/lb LWK. Microsoft Windows NT 6.1.7601 Service Pack 1 Limitation is calculated using the formula 0.28 ) 0.30 (V-0.4) where V is the same as note (1). Microsoft Windows NT 6.1.7601 Service Pack 1