Section 141.09. Well screen.  


Latest version.
  • (1) Specifications. All permanent groundwater monitoring well screens shall be constructed of material which is nonreactive with the constituents in soils and groundwater at the monitoring location. The well screen may not be hand cut and may not be wrapped with filter cloth. The well screen slot size shall be sized to retain at least 90% of the grain size of the collapsed formation, based on a sieve analysis, when collapsed formation is used as filter pack material or at least 90% of the grain size of the filter pack, based on a sieve analysis, if material other than collapsed formation is used. Well screens on water table observation wells may not exceed 15 feet in length. Well screens on piezometers installed for the purpose of determining the elevation of the potentiometric surface may not exceed 5 feet in length.
    (2) Assembly and installation. All well screens shall be permanently joined to the well casing by flush threaded joints. All joints shall be watertight. All well screens shall be centered in the borehole. Monitoring wells installed in bedrock using an open borehole may be constructed without a well screen.
History: Cr. Register, January, 1990, No. 409 , eff. 2-1-90; am. (1), Register, June, 1991, No. 426 , eff. 7-1-91.

Note

Well screens for wells other than the water table observation wells and piezometers identified above may vary in length. Microsoft Windows NT 6.1.7601 Service Pack 1 Figure 1.
Typical water table observation well and piezometer construction details.
- See PDF for diagram PDF
Microsoft Windows NT 6.1.7601 Service Pack 1