Wisconsin Administrative Code (Last Updated: January 10, 2017) |
![]() |
Agency DHS. Department of Health Services |
![]() |
Chapters 110-199. Health |
![]() |
Chapter 157. Radiation Protection |
![]() |
SubChapter IV. Radiation Safety Requirements for Industrial Radiographic Operations |
Section 157.48. Specific requirements for radiographic personnel performing industrial radiography.
Latest version.
- (1) Job site requirements. At a job site, a licensee or registrant shall supply all the following:(a) At least one operable, calibrated survey instrument for each exposure device or radiation machine in use.(b) A current whole body personnel monitor, TLD, film badge or similar approved device for each person performing radiographic operations.(c) An operable, calibrated pocket dosimeter with a range of zero to 200 milliroentgens for each person performing radiographic operations.(d) An operable, calibrated, alarming ratemeter for each person performing radiographic operations using a radiographic exposure device.(e) Barrier ropes and signs as required in subch. III .(2) Proof of certification. Each radiographer at a job site shall carry on their person a valid certification ID card issued by a certifying entity.