Section 463.02. Definitions.  


Latest version.
  • For terms not defined in this section, the definitions contained in chs. NR 400 and 460 apply to the terms used in this subchapter, with definitions in ch. NR 460 taking priority over definitions in ch. NR 400 . In addition, the definitions in this section apply to the terms used in this subchapter. If this section defines a term which is also defined in ch. NR 400 or 460 , the definition in this section applies in this subchapter rather than the definition in ch. NR 400 or 460 . In this subchapter:
    (1)  "Add-on air pollution control device" means equipment installed in the ventilation system of chromium electroplating and anodizing tanks for the purposes of collecting and containing chromium emissions from the tanks.
    (2)  "Air pollution control technique" means any method, such as an add-on air pollution control device or a chemical fume suppressant, that is used to reduce chromium emissions from chromium electroplating and chromium anodizing tanks.
    (3)  "Base metal" means the metal or metal alloy that comprises the workpiece.
    (4)  "Bath component" means the trade, brand or chemical name of each component in trivalent chromium plating baths.
    (5)  "Chemical fume suppressant" means any chemical agent that reduces or suppresses fumes or mists at the surface of an electroplating or anodizing bath.
    (6)  "Chromic acid" means the common name for chromium anhydride (CrO 3 ).
    (7)  "Chromium anodizing" means the electrolytic process by which an oxide layer is produced on the surface of a base metal for functional purposes, such as corrosion resistance or electrical insulation, using a chromic acid solution. In chromium anodizing, the part to be anodized acts as the anode in the electrical circuit, and the chromic acid solution, with a concentration typically ranging from 50 to 100 grams per liter (g/L), serves as the electrolyte.
    (8)  "Chromium anodizing tank" means the receptacle or container along with the following accompanying internal and external components needed for chromium anodizing: rectifiers fitted with controls to allow for voltage adjustments, heat exchanger equipment, circulation pumps and air agitation systems.
    (8m)  "Chromium electroplating tank" means the receptacle or container along with the following accompanying internal and external components needed for chromium electroplating: rectifiers, anodes, heat exchanger equipment, circulation pumps and air agitation systems.
    (9)  "Composite mesh-pad system" means an add-on air pollution control device typically consisting of several mesh-pad stages. The purpose of the first stage is to remove large particles. Smaller particles are removed in the second stage, which consists of the composite mesh pad. A final stage may remove any reentrained particles not collected by the composite mesh pad.
    (10)  "Decorative chromium electroplating" means the process by which a thin layer of chromium (typically 0.003 to 2.5 m m) is electrodeposited on a base metal, plastic or undercoating to provide a bright surface with wear and tarnish resistance. In this process, the part serves as the cathode in the electrolytic cell and the solution serves as the electrolyte. Typical current density applied during this process ranges from 540 to 2,400 amperes per square meter (A/m 2 ) for total plating times ranging between 0.5 to 5 minutes.
    (11)  "Electroplating or anodizing bath" means the electrolytic solution used as the conducting medium in which the flow of current is accompanied by movement of metal ions for the purposes of electroplating metal out of the solution onto a workpiece or for oxidizing the base material.
    (12)  "Emission limitation" means the concentration of total chromium allowed to be emitted expressed in milligrams per dry standard cubic meter (mg/dscm), or the allowable surface tension expressed in dynes per centimeter (dynes/cm).
    (12m)  "Enclosed hard chromium electroplating tank" means a chromium electroplating tank that is equipped with an enclosing hood and ventilated at half the rate or less than that of an open surface tank of the same surface area.
    (13)  "Existing" means any hard chromium electroplating tank, decorative chromium electroplating tank or chromium anodizing tank the construction or reconstruction of which was commenced on or before December 16, 1993.
    (14)  "Facility" means the major or area source at which chromium electroplating or chromium anodizing is performed.
    (15)  "Fiber-bed mist eliminator" means an add-on air pollution control device that removes contaminants from a gas stream through the mechanisms of inertial impaction and Brownian diffusion. These devices are typically installed downstream of another control device, which serves to prevent plugging, and consist of one or more fiber beds. Each bed consists of a hollow cylinder formed from 2 concentric screens; the fiber between the screens may be fabricated from glass, ceramic plastic or metal.
    (16)  "Foam blanket" means the type of chemical fume suppressant that generates a layer of foam across the surface of a solution when current is applied to that solution.
    (17)  "Fresh water" means water, such as tap water, that has not been previously used in a process operation or, if the water has been recycled from a process operation, it has been treated and meets the effluent guidelines for chromium wastewater.
    (18)  "Hard chromium electroplating" or "industrial chromium electroplating" means a process by which a thick layer of chromium (typically 1.3 to 760 m m) is electrodeposited on a base material to provide a surface with functional properties such as wear resistance, a low coefficient of friction, hardness and corrosion resistance. In this process, the part serves as the cathode in the electrolytic cell and the solution serves as the electrolyte. The hard chromium electroplating process is performed at current densities typically ranging from 1,600 to 6,500 A/m 2 for total plating times ranging from 20 minutes to 36 hours depending upon the desired plate thickness.
    (19)  "Hexavalent chromium" means the form of chromium in a valence state of +6.
    (20)  "Large, hard chromium electroplating facility" means a facility that performs hard chromium electroplating and has a maximum cumulative potential rectifier capacity greater than or equal to 60 million ampere-hours per year (A-hr/yr).
    (21)  "Maximum cumulative potential rectifier capacity" means the summation of the total installed rectifier capacity associated with the hard chromium electroplating tanks at a facility, expressed in amperes, multiplied by the maximum potential operating schedule of 8,400 hours per year and 0.7, which assumes that electrodes are energized 70% of the total operating time. The maximum potential operating schedule is based on operating 24 hours per day, 7 days per week, 50 weeks per year.
    (22)  "New source" or "new tank" means any hard chromium electroplating, decorative chromium electroplating or chromium anodizing source or tank the construction or reconstruction of which is commenced after December 16, 1993.
    (22m)  "Open surface hard chromium electroplating tank" means a chromium electroplating tank that is ventilated at a rate consistent with good ventilation practices for open tanks.
    (23)  "Operating parameter value" means a minimum or maximum value established for a control device or process parameter which, if achieved by itself or in combination with one or more other operating parameter values, determines that an owner or operator is in continual compliance with the applicable emission limitation or standard.
    (24)  "Packed-bed scrubber" means an add-on air pollution control device consisting of a single or double packed bed that contains packing media on which the chromic acid droplets impinge. The packed-bed section of the scrubber is followed by a mist eliminator to remove any water entrained from the packed-bed section.
    (25)  "Research or laboratory operation" means an operation whose primary purpose is for research and development of new processes and products, that is conducted under the close supervision of technically trained personnel, and that is not involved in the manufacture of products for commercial sale, except in a de minimis manner.
    (26)  "Small, hard chromium electroplating facility" means a facility that performs hard chromium electroplating and has a maximum cumulative potential rectifier capacity less than 60 million A-hr/yr.
    (27)  "Stalagmometer" means an instrument used to measure the surface tension of a solution by determining the mass of a drop of liquid by weighing a known number of drops or by counting the number of drops obtained from a given volume of liquid.
    (28)  "Surface tension" means the property, due to molecular forces, that exists in the surface film of all liquids and tends to prevent liquid from spreading.
    (29)  "Tank operation" means the use of a tank for chromium electroplating or a chromium anodizing through the application of current or voltage. Tank operation ceases when the current or voltage is turned off.
    (30)  "Tensiometer" means an instrument used to measure the surface tension of a solution by determining the amount of force needed to pull a ring from the liquid surface. The amount of force is proportional to the surface tension.
    (31)  "Trivalent chromium" means the form of chromium in a valence state of +3.
    (32)  "Trivalent chromium process" means the process used for electrodeposition of a thin layer of chromium onto a base material using a trivalent chromium solution instead of a chromic acid solution.
    (33)  "Wetting agent" means the type of chemical fume suppressant that reduces the surface tension of a liquid.
Cr. Register, September, 1997, No. 501 , eff. 10-1-97; CR 05-039 : am. (intro.), (8), (27) and (30), cr. (8m), (12m) and (22m) Register February 2006 No. 602 , eff. 3-1-06.

Note

Since for trivalent chromium baths, the bath composition is proprietary in most cases, the trade or brand name for each component may be used. However, ss. NR 463.103 (2) (n) and 463.106 (9) (a) 3. require identification by chemical name of the wetting agent contained in that component. Microsoft Windows NT 6.1.7601 Service Pack 1 Another term for fume suppressant is mist suppressant. Microsoft Windows NT 6.1.7601 Service Pack 1